KROHNE OPTIFLEX 8200 C Handbook page 98

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPERATION
6
Menu
Function
No.
2.8.2
Conversion unit
2.8.3
Input Table
2.8.4
Delete Table
2.9.0 Reset
2.9.0 Reset
2.9.0 Reset
2.9.0 Reset
2.9.1
Restart Device
2.9.2
Reset Factory
2.10.0 History
2.10.0 History
2.10.0 History
2.10.0 History
A log of device errors. Push [> > > > ] to read the errors. Push [ ] or [ ] to scroll up or down the list. Each error is
identified by a code. Push [> > > > ] again to show the number of incidents and the time since the last incident in
days, hours, minutes and seconds. For more data about errors, refer to
115.
1 "INTERFACE LEVEL", "INTERFACE CONVERSION", "INTERFACE DISTANCE", "INTERFACE DIST. CONV.", "LAYER" and "LAYER CON-
VERSION" are only available if you included the Interface Capability option in the customer order. You must also set Application Type
to "LEVEL + INTERFACE MIXED", "LEVEL + INTERFACE UNMIXED" or "INTERFACE (FULLY SUBMERGED PROBE)". "LEVEL CONVER-
SION", "DISTANCE CONV.", "INTERFACE CONVERSION", "INTERFACE DIST. CONV." and "LAYER CONVERSION" are only available if
you made a conversion table (strapping table).
2 Units and range depend on the output function, length unit and volume unit selected
3 This depends on the data given in the customer order
4 "CURRENT" and "RELAY" are only available if a second output option is in the customer order
5 "INTERFACE LEVEL", "INTERFACE CONVERSION", "INTERFACE DISTANCE", "INTERFACE DIST. CONV.", "LAYER" and "LAYER CON-
VERSION" are only available if you included the Interface Capability option in the customer order. You must also set Application Type
to "LEVEL + INTERFACE MIXED", "LEVEL + INTERFACE UNMIXED" or "INTERFACE (FULLY SUBMERGED PROBE)". "LEVEL CONVER-
SION", "DISTANCE CONV.", "INTERFACE CONVERSION", "INTERFACE DIST. CONV." and "LAYER CONVERSION" are only available if
you made a conversion table (strapping table). "RELAY STATE" is only available if menu item 2.4.6 Optional Output Mode is set to "RE-
LAY".
Default values for menu item 2.3.2 Blocking Distance
Probe type
Ø8 mm / 0.32¨single rod
Ø4 mm / 0.16¨ single cable
Ø42 mm / 1.65¨ coaxial
Device without a probe (spare part)
98
Function description
The conversion unit used to make the
conversion table.
The device uses a conversion table
(strapping table) to convert measurements
to volume and mass readings. The
readings are shown in normal mode. Go to
this menu item and enter the entry
number (01...30). Then enter the level and
the related volume / mass value for that
entry. Push [^ ^ ^ ^ ] to confirm the entry
values. Continue the procedure until the
device has data for all the entries. For
How to configure the
more data, refer to
device to measure volume or mass
page 105.
This menu item erases the data in the
conversion table.
This menu item starts the device again.
If you set this menu item to "YES", the
device goes back to its initial settings (set
by the manufacturer in the factory).
www.krohne.com
Selection list or range
of values
kg, t, Ston, Lton, m, cm,
mm, in (inches), ft (feet),
m3, L, gal (US gallon),
Imp (imperial gallon),
ft3, bbl, m3/h, ft3/h
min. 2 entries
max. 30 entries
(level / volume or mass)
on
YES, NO
YES, NO
YES, NO
Status and error messages
Blocking distance
[mm]
250
350
100
350
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S
Default
0 entries
NO
NO
NO
on page
[inches]
9.84
13.78
3.94
13.78