KROHNE OPTIFLEX 8200 C Handbook page 138

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

SERVICE
7
Item
(15)
(16)
(17)
(17)
(17)
(17)
(18)
(19)
(20)
(20)
(20)
(20)
(21)
(22)
(22)
(22)
(22)
(23)
(24)
(24)
(24)
(24)
(25)
(26)
(27)
(28)
(29)
(29)
(29)
(29)
(30)
(30)
(30)
(30)
(31)
(31)
(31)
(31)
(32)
1 This depends on the device options
2 PCB = Printed circuit board
3 PCBs are potted with polyamide
4 This depends on the output option
138
Description
Blocker
"T" housing
PCB types 1, 2 or 3
PCB types 1, 2 or 3
PCB types 1, 2 or 3
PCB types 1, 2 or 3
4
Brace type 1
1
Guide
1
PCB for display screen
PCB for display screen
PCB for display screen
PCB for display screen
1
Cover
Feedthrough for Ex d /second output compartment
Feedthrough for Ex d /second output compartment
Feedthrough for Ex d /second output compartment
Feedthrough for Ex d /second output compartment
Ex d housing
1
PCB types 1, 2, 3, 4 or 5
PCB types 1, 2, 3, 4 or 5
PCB types 1, 2, 3, 4 or 5
PCB types 1, 2, 3, 4 or 5
1
Brace type 4 or 5
1
Cover
Blocking part
Housing wall support
Cable
Cable
Cable
Cable
PCB
PCB
PCB
PCB
1
PCB
PCB
PCB
PCB
1
Probe electronics housing
1
www.krohne.com
OPTIFLEX 8200 C/F/S
Material
PA 66
aluminium or stainless steel
3
PA 66
EPDM
3
aluminium or stainless steel +
PC
ferrite + rubber + cables
ferrite + rubber + cables
ferrite + rubber + cables
ferrite + rubber + cables
aluminium or stainless steel
3
brass CW614N M nickel finish
aluminium or stainless steel
stainless steel
aluminium or stainless steel
Option 1
Option 1
Option 1
Option 1
Wire: tinned copper wire
Wire: tinned copper wire
Wire: tinned copper wire
Wire: tinned copper wire
(24AWG)
(24AWG)
(24AWG)
(24AWG)
Insulation: datalene
Insulation: datalene
Insulation: datalene
Insulation: datalene
Core: two twisted pairs
Core: two twisted pairs
Core: two twisted pairs
Core: two twisted pairs
individually shielded with
individually shielded with
individually shielded with
individually shielded with
Beldfoil aluminium-polyester)
Beldfoil aluminium-polyester)
Beldfoil aluminium-polyester)
Beldfoil aluminium-polyester)
1
Option 2
Option 2
Option 2
Option 2
Wire: bare copper wire
Wire: bare copper wire
Wire: bare copper wire
Wire: bare copper wire
(22AWG)
(22AWG)
(22AWG)
(22AWG)
Insulation: foamed
Insulation: foamed
Insulation: foamed
Insulation: foamed
Polyethylene (PE) with skin
Polyethylene (PE) with skin
Polyethylene (PE) with skin
Polyethylene (PE) with skin
Ø2.1mm / 0.08
Ø2.1mm / 0.08¨
Ø2.1mm / 0.08
Ø2.1mm / 0.08
Core: 4 wires
Core: 4 wires
Core: 4 wires
Core: 4 wires
Jacket: Polyvinylchloride (PVC)
Jacket: Polyvinylchloride (PVC)
Jacket: Polyvinylchloride (PVC)
Jacket: Polyvinylchloride (PVC)
1
3
3
aluminium or stainless steel
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
1
1
1
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s