KROHNE OPTIFLEX 8200 C Handbook page 192

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

DESCRIPTION OF HART INTERFACE
9
Status
Test/Reset
Date and Time
Read Error History
192
Device Specific Status
Loop Test / Loop Test I2 / Diagnostic / Restart Device / Reset Factory / Reset
Configuration Changed Flag
Rd
Current Date
/ Current Time
www.krohne.com
Failures:
Oscillator Frequency Failure / Current Output Drift /
Sensor ROM error / Sensor RAM error / Sensor
EEPROM error / Converter ROM error / Converter
RAM error / Converter EEPROM error / Sensor
Processing Failure / Sensor Not Compatible /
Temperature Out of Range / Internal
Communication Error / Sensor Voltage Error /
Converter Voltage Error / Reference Pulse Lost
Error / Level Pulse Lost Error / Overfill (Error) /
Empty (Error) / Analog Output 2 Drift / Sensor - Time
Out DMA / Sensor - Time Out Lock PLL / Sensor -
Time Out SPI Read / Sensor - Time Out SPI Write /
Sensor - Time Out Switch Clock / Sensor - Time Out
Load ASIC / Sensor - Time Out SPI R/W / Sensor -
Voltage 5V Error / Sensor - Voltage 2.5V Error /
Sensor - Voltage 1.5V Error / Sensor - Time Out
Power Good / Relay State Not Correct / Clock Pulse
Generator KO / Clock Sampler & Hold KO / RTC
Failure - Time Stamp KO / Interface - Lost (Error) /
Interface - Overfill (Error) / Interface - Empty
(Error) / Leak Detected (Error)
Warning Maintenance Required:
Flange Lost / Snapshot Invalid / Auto Probe Length
Invalid / Reference Position Outside Range / Audio
Signal Offset Outside Range / Temperature Below -
35°C / Temperature Above +75°C / Leak Detected
(Warning) / Sensor - Temperature Too Low / Sensor
- Temperature Too High / Auto Setup Required /
Reference Pulse Amplitude Anomaly / Reference
Pulse Width Anomaly
Warning Out Of Specification:
Level Empty (Warning) / Local Operation on the
device (Warning) / Overfill (Warning) / Level Lost
(Warning) / Temperature Out of Range (Warning) /
Interface - Lost (Warning) / Interface - Empty
(Warning) / Interface - Overfill Warning) / Layer
Empty
Info:
First Start / Epsilon R Calculation Frozen / Epsilon R
Value Low / Epsilon R Value High / Temperature
Outside Operating Range of HMI / Measure Not
Updated / Snapshot Distance Validation Not
Required / Dielectric Gas - Value Low / Dielectric
Gas - Calcul.Frozen / FPGA Update / Optional Output
Detected / Relay State Closed
Rd
/ Set Date and Time
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en