KROHNE OPTIFLEX 8200 C Handbook page 89

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPTIFLEX 8200 C/F/S
Menu
Function
No.
1.6.2
Mechanic Type
Process Type
Probe Type
1 "INTERFACE LEVEL", "INTERFACE CONVERSION", "INTERFACE DISTANCE", "INTERFACE DIST. CONV.", "LAYER" and "LAYER CON-
VERSION" are only available if you included the Interface Capability option in the customer order. You must also set Application Type
to "LEVEL + INTERFACE MIXED", "LEVEL + INTERFACE UNMIXED" or "INTERFACE (FULLY SUBMERGED PROBE)". "LEVEL CONVER-
SION", "DISTANCE CONV.", "INTERFACE CONVERSION", "INTERFACE DIST. CONV." and "LAYER CONVERSION" are only available if
you made a conversion table (strapping table).
2 Units and range depend on the output function, length unit and volume unit selected
3 This depends on the data given in the customer order
4 "CURRENT" and "RELAY" are only available if a second output option is in the customer order
5 "LEVEL + INTERFACED MIXED", "LEVEL + INTERFACE MIXED" and "INTERFACE (FULLY SUBMERGED PROBE) are only available if the
device has the Interface Capability option. "LEVEL WITH GAS PHASE COMPENSATION" is only available if the device has the Dynamic
Gas-phase Compensation (DGC) option.
Supervisor menu
The Advanced Setup menu is a list of procedures that have a more functions than the Auto Setup
procedure.
Push the [> > > > ] to go to Configuration mode. Enter the Supervisor password.
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
Function description
The process seal option for the device.
The probe option for the device. If the
measurement screen is set to SI units,
then probe dimensions are given in
millimetres. If the measurement screen is
set to Imperial / US Customary units, then
probe dimensions are given in inches.
www.krohne.com
OPERATION
Selection list or range
of values
CERAMIC HT-HP
THREADED,
CERAMIC HT-HP
FLANGE,
DUAL CERAMIC
THREADED, DUAL
CERAMIC FLANGE,
OTHER PROCESS
SI units:
SI units:
SI units:
SI units:
OTHER PROBE,
SINGLE ROD Ø8,
COAX Ø42, CABLE Ø4
C/W 20x100, CABLE Ø4 +
TUIRNBUCKLE, CABLE
Ø4 + CHUCK, CABLE Ø4
+ THREADED END,
CABLE Ø4 CRIMPED
END, CABLE Ø4 OPEN
END, CABLE Ø4 C/W
60x20
Imperial / US Customary
Imperial / US Customary
Imperial / US Customary
Imperial / US Customary
units:
units:
units:
units:
OTHER PROBE,
SINGLE ROD Ø0.32¨,
COAX Ø1.65¨, CABLE
Ø0.16¨ C/W 0.79x3.94¨,
CABLE Ø0.16¨ +
TUIRNBUCKLE, CABLE
Ø0.16¨ + CHUCK, CABLE
Ø0.16¨ + THREADED
END, CABLE Ø0.16¨
CRIMPED END, CABLE
Ø0.16¨ OPEN END,
CABLE Ø0.16¨ C/W
2.36x0.79¨
6
Default
3
3
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s

Table of Contents