KROHNE OPTIFLEX 8200 C Handbook page 72

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPERATION
6
INFORMATION!
If you push a keypad button for less than 2 seconds, then you can use the standard function. If
you push a keypad button for more than 2 seconds, then you can use the "Hot key" function. For
more data, refer to the "Keypad function" table in this section.
Measurement definitions
Measurement type
LEVEL
DISTANCE
INTERFACE LEVEL
INTERFACE
DISTANCE
LAYER
LAYER CONVERSION
SENSOR
TEMPERATURE
CONV. TEMPERATURE This is a display and an output function option.
OUTPUT %
OUTPUT I
DIELECTRIC GAS
72
Description
This is a display and an output function option.
It is the height from the top of the tank to the
surface of the liquid contents (tank height -
distance).
This is a display and an output function option.
It is the distance from the face of the flange to
the surface of the liquid contents of the tank.
This is a display and an output function option.
It is shown if you included the interface
measurement option in the customer order. If
the tank contains 2 liquids, it is the height from
the bottom of the tank to the interface between
the top liquid and the bottom liquid (tank height
- interface distance)
This is a display and an output function option.
It is shown if you included the interface
measurement option in the customer order. If
the tank contains 2 liquids, is the distance from
the face of the flange to the interface between
the top liquid and the bottom liquid.
This is a display and an output function option.
It is shown if you included the interface
measurement option in the customer order. If
the tank contains 2 liquids, it gives the
thickness of top product. The layer must be
more than 50 mm or 2¨ for accurate
measurement of level and/or interface.
This is a display and an output function option.
It is shown if you included the interface
measurement option in the customer order. It
gives the volume or mass of the top liquid when
there are 2 or more liquids in the tank. This
data is available if you prepare a volume or
mass table in configuration mode. For data on
how to prepare the conversion table, refer to
How to configure the device to measure
volume or mass
on page 105.
This is a display and an output function option.
The temperature of the sensor electronics.
The temperature in the signal converter
housing.
The percentage of the current output.
0% = 4 mA. 100% = 20 mA.
The current output of the device.
This is a display and an output function option.
The dielectric constant (ε
tank. This value is calculated automatically if
the device has the Dynamic Gas-phase
Dynamic Gas-phase
Dynamic Gas-phase
Dynamic Gas-phase
Compensation
Compensation
Compensation option. Go to menu item 1.5.2
Compensation
Gas Phase Comp.. If this option does not show
the message "Option is active", enter a code.
You must buy this option from your supplier.
Your supplier will then give you the code.
www.krohne.com
m, cm, mm, in (inches),
ft (feet)
m, cm, mm, in (inches),
ft (feet)
m, cm, mm, in (inches),
ft (feet)
m, cm, mm, in (inches),
ft (feet)
m, cm, mm, in (inches),
ft (feet)
kg, t, Ston, Lton, m, cm, mm,
in, ft, m3, L, gal, Imp, ft3, bbl,
m3/h, ft3/h
°C, K, °F, °R
°C, K, °F, °R
%
mA
) of the gas in the
r
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S
Available units

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s

Table of Contents