KROHNE OPTIFLEX 8200 C Handbook page 148

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

TECHNICAL DATA
8
Current output load
Cable entry
Cable gland
Signal cable – remote version
Cable entry capacity (terminal)
Input and output
Measured variable
Current output / HART®
Current output / HART
Current output / HART
Current output / HART
Output 1 signal
Output 2 signal
Resolution
Temperature drift (analog)
Temperature drift (digital)
Error signal options
Switch output - relay (option)
Switch output - relay (option)
Switch output - relay (option)
Switch output - relay (option)
Description
Maximum switching capacity
Voltage range
Current range
R
on-state
Switching capacity range
Display and user interface
User interface options
Languages
148
[Ω] ≤ ((U
Non-Ex / Ex i: R
Non-Ex / Ex i:
Non-Ex / Ex i:
Non-Ex / Ex i:
L
Minimum power supply voltage
For more data, refer to
[Ω] ≤ ((U
Ex d, output 1:
Ex d, output 1: R
Ex d, output 1:
Ex d, output 1:
L
For more data, refer to
Minimum power supply voltage
[Ω] ≤ ((U
Ex d, output 2:
Ex d, output 2: R
Ex d, output 2:
Ex d, output 2:
L
Minimum power supply voltage
For more data, refer to
M20×1.5; ½ NPT
Standard: none
Options: M20×1.5, others are available on request
Cable diameter, output 1:
non-Ex / Ex i: 6...7.5 mm / 0.24...0.30¨; Ex d: 7...10 mm / 0.28...0.39¨;
Cable diameter, output 2:
non-Ex / Ex i: 6...12 mm / 0.24...0.47¨; Ex d: 7...12 mm / 0.28...0.47¨
None for non-Ex devices (4-wire shielded cable of max. length 100 m / 328 ft to be
supplied by the customer). Supplied with all Ex-approved devices. For more data,
Remote device data
refer to
0.5...2.5 mm²
Time between the emitted and received signal
4...20 mA HART® or 3.8...20.5 mA acc. to NAMUR NE 43
4...20 mA or 3.8...20.5 mA acc. to NAMUR NE 43
±3 µA
Typically 50 ppm/K
Max. ±15 mm for the full temperature range
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43; Hold (frozen value – not available if
the output agrees with NAMUR NE 43 or the device is approved for safety-related
systems (SIL))
Relay (1 contact, normally open). SIS 2 Sensitive Series (ELESTA GmbH).
48 V AC / 6 A; 24 V DC / 6 A (according to IEC 60947-5-1)
Category AC-1: 5...48 V AC / Category DC-1: 2...24 V DC
0.003...6 A
< 100 mΩ at 6 V / 100 mA
0.04...288 W (VA)
LCD display (128 × 64 pixels in 8-step greyscale with 4-button keypad)
English, German, French, Italian, Spanish, Portuguese, Japanese, Chinese
(simplified), Russian, Czech, Polish and Turkish
www.krohne.com
-11.5 V)/22 mA).
ext
-13.5 V)/22 mA).
ext
-11.5 V)/22 mA).
ext
on page 56
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S
on page 156.
on page 156.
on page 156.
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s

Table of Contents