KROHNE OPTIFLEX 8200 C Handbook page 63

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPTIFLEX 8200 C/F/S
Two current outputs
Figure 4-20: Electrical connections for non-Ex devices (two current outputs)
1 Power supply
2 Resistor for HART® communication
3 Optional connection to the grounding terminal
4 Output 1 and 2: 11.5...30 V DC for an output of 22 mA at the terminals
NOTE: Use a separate power supply to energize output 2
5 Device
6 Connector for the optional second output
One current output and one switch output - relay
Figure 4-21: Electrical connections for non-Ex devices (one current output and one switch output - relay)
1 Power supply
2 Resistor for HART® communication
3 Optional connection to the grounding terminal
4 Output 1: 11.5...30 V DC for an output of 22 mA at the terminals
5 Switch power supply (2): 11.5...34 V DC / 30 mA
NOTE: Use a separate power supply to energize the switch output - relay option
6 Device
7 Connector for the switch output - relay
8 PLC (for example)
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
ELECTRICAL CONNECTIONS
www.krohne.com
4
63