INSTALLATION
3
CAUTION!
The standpipe must be electrically conductive. If the standpipe is not made of metal, obey the
•
instructions for empty space around the probe. For more data, refer to General requirements
on page 26
•
The standpipe must be straight. There must be no changes in diameter from the device
process connection to the bottom of the standpipe.
The standpipe must be vertical.
•
Recommended surface roughness: <
•
•
The bottom of the stilling well must be open.
Adjust the probe to the center of the standpipe.
•
Make sure that there are no deposits at the bottom of the standpipe which can cause
•
blockage of the process connections.
•
Make sure that there is liquid in the standpipe.
Floating roofs
If the device is for a tank with a floating roof, install it in a stilling well.
30
.
www.krohne.com
0.1 mm / 0.004
.
±
¨
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S