OPTIFLEX 8200 C/F/S
Menu
Function
No.
2.7.0 Display
2.7.0 Display
2.7.0 Display
2.7.0 Display
2.7.1
Language
2.7.2
Display Length
Unit
2.7.3
Display
Conversion Unit
2.7.4
Password Yes/No
2.7.5
Password
2.7.6
Contrast
2.7.7
Clock setting
2.7.8
Display Mode
2.8.0 Conversion Table
2.8.0 Conversion Table
2.8.0 Conversion Table
2.8.0 Conversion Table
2.8.1
Length unit
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
Function description
Data can be shown in one of the languages
stored in the device. Make a selection from
the list.
The length unit shown in normal mode.
The length, volume or mass conversion
unit for the conversion table and shown in
normal mode.
If it is necessary to protect your settings in
the supervisor menu with a password, set
this menu item to YES
YES
YES.
YES
This changes the password for the
supervisor menu. Push the buttons up to 6
times in any order. This will be the new
password. To confirm the change, enter
the new password a second time. For
Protection of the device
more data, refer to
settings
on page 102.
The contrast control for the display
screen. You can select a shade of grey
between "no contrast" (level "0") and
"black" (level "9").
Give the time format, date format, time
and date.
The measurement type shown in normal
mode. If this function is set to a
measurement type (e.g. Level), the device
will always go back to this default
measurement type in normal mode after
15 minutes. If this function is set to
"DISABLE" and the device is set to a
measurement type in normal mode, the
device will not go back to the default
measurement type after 15 minutes.
The length unit used to make the
conversion table.
www.krohne.com
OPERATION
Selection list or range
of values
English, German,
French, Italian,
Portuguese, Spanish,
Czech, Polish, Chinese
(simplified), Japanese,
Russian, Turkish
m, cm, mm, in (inches),
ft (feet)
kg, t, Ston, Lton, m, cm,
mm, in (inches), ft (feet),
m3, L, gal (US gallon),
Imp (imperial gallon),
ft3, bbl, m3/h, ft3/h
YES, NO
min-max:
0...9
Date/Clock format:
YYYY/MM/DD 24h,
DD/MM/YYYY 12h,
DD/MM/YYYY 24h,
YYYY/MM/DD 12h
Set Clock
Set Date
LEVEL, LEVEL
CONVERSION,
DISTANCE, DISTANCE
CONV., INTERFACE
LEVEL, INTERFACE
CONVERSION,
INTERFACE DISTANCE,
INTERFACE DIST.
CONV., LAYER, LAYER
CONVERSION,
DIELECTRIC PRODUCT,
DIELECTRIC GAS,
OUTPUT I, OUTPUT %,
RELAY STATE,
CONVERTER
TEMPERATURE,
SENSOR
TEMPERATURE, TIME,
DATE
5
m, cm, mm, in (inches),
ft (feet)
6
Default
English
m
kg
YES
[> > > > ], [^ ^ ^ ^ ], [ ],
[ ], [> > > > ] and [^ ^ ^ ^ ]
6
YYYY/MM/DD
24h
LEVEL
97