KROHNE OPTIFLEX 8200 C Handbook page 158

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

TECHNICAL DATA
8
Pressure and temperature limits (PN10...100 / Class 150...600)
Figure 8-5: Operating limits (PN10...100 / Class 150...600): graph of process pressure (barg) against process
connection temperature (°C)
Figure 8-6: Operating limits (PN10...100 / Class 150...600): graph of process pressure (psig) against process connection
temperature (°F)
1 Process pressure, P
2 Process connection temperature, T [°C]
3 Process pressure, P
4 Process connection temperature, T [°F]
5 Flange connection, PN100 (EN 1092-1) or Class 600 (ASME B16.5)
6 Flange connection, PN63 (EN 1092-1)
7 Flange connection, PN40 (EN 1092-1) or Class 300 (ASME B16.5)
8 Flange connection, PN25 (EN 1092-1)
9 Flange connection, PN16 (EN 1092-1) or Class 150 (ASME B16.5)
10 Flange connection, PN10 (EN 1092-1)
158
[barg]
s
[psig]
s
www.krohne.com
OPTIFLEX 8200 C/F/S
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s

Table of Contents