SERVICE
7
Figure 7-2: Parts of the device (refer to "Parts list" table)
Procedure: how to disassemble the sensor extension
• Remove the wall fitting (1).
• Remove the nut (2), the screws (8) and the screw (12).
• Remove the connectors (4)
i
You can send the parts to the approved location for waste treatment or recycling.
134
connectors (4) from the cable (11)
connectors (4)
connectors (4)
www.krohne.com
cable (11).
cable (11)
cable (11)
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en