KROHNE OPTIFLEX 8200 C Handbook page 86

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPERATION
6
Menu
Function
No.
1.3.2
Output I2 Setup
1.3.2
Optional Output
mode
1.3.2
Output Function
I2
Scale 4mA I2
Scale 20mA I2
86
Function description
Use this quick set-up procedure to give the settings for optional output 2.
This function operates the optional second
output (output 2).
If you set this function to "CURRENT", the
second output supplies 4...20 mA. Give the
settings for this current output in Output
Function I2, Scale 4mA I2
Function I2
Function I2
Function I2
Scale 4mA I2
Scale 4mA I2
Scale 4mA I2 and Scale 20mA
I2 I2 I2 I2.
If you set this function to "RELAY", the
second output supplies a switch signal.
Give the settings for this relay signal in
Switch Function
Switch Function
Switch Function, Set Point/Threshold
Switch Function
Set Point/Threshold,
Set Point/Threshold
Set Point/Threshold
Alarm Mode and Hysteresis
Alarm Mode
Hysteresis. If Switch
Alarm Mode
Alarm Mode
Hysteresis
Hysteresis
Function
Function
Function
Function is set to "ERROR LIST", set a
condition in the menu item Error List
The output function for output 2. Make a
selection from a list of output functions to
scale the current values in relation to a
given point (usually the device process
connection or the tank bottom). The output
current value is shown on a bar graph in
normal mode if the measurement name
(displayed measurement) is the same as
the output function. Conversion
parameters (DISTANCE CONV., LEVEL
CONVERSION etc.) are shown if there is
volume or mass data in menu item 1.2.0
Conversion Setup.
Conversion Setup
Conversion Setup
Conversion Setup
This function is available if Optional Output
Mode is set to "CURRENT".
Mode
Mode
Mode
This function gives a measurement value
to 4 mA (output 2).
This function is available if Optional Output
Mode
Mode is set to "CURRENT".
Mode
Mode
This function gives a measurement value
to 20 mA (output 2).
This function is available if Optional Output
Mode is set to "CURRENT".
Mode
Mode
Mode
www.krohne.com
Selection list or range
of values
DISABLE, CURRENT,
RELAY
Output
Output
Output
Scale 20mA
Scale 20mA
Scale 20mA
Switch
Switch
Switch
Error List
Error List
Error List only.
LEVEL,
LEVEL CONVERSION,
DISTANCE,
DISTANCE CONV.,
INTERFACE LEVEL,
INTERFACE
CONVERSION,
INTERFACE DISTANCE,
INTERFACE DIST.
CONV., LAYER,
LAYER CONVERSION,
1.2.0
1.2.0
1.2.0
DIELECTRIC PRODUCT,
DIELECTRIC GAS,
CONVERTER
Optional Output
Optional Output
Optional Output
TEMPERATURE,
SENSOR TEMPERATURE
1
min-max:
Optional Output
Optional Output
Optional Output
min-max:
Optional Output
Optional Output
Optional Output
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S
Default
3
4
DISTANCE
3
2
3
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiflex 8200 fOptiflex 8200 s

Table of Contents