OPTIFLEX 8200 C/F/S
Equipment needed
Figure 4-15: Equipment needed to prepare the signal cable
1 Remote converter
2 Probe electronics housing
3 Signal cable (supplied on request for non-Ex devices) – for more data, refer to
by the customer
4 Small slotted-tip screwdriver (not supplied)
Connections between the remote converter and the probe electronics housing
Figure 4-16: Connections between the remote converter and the probe electronics housing
1 Remote converter
2 Probe electronics housing
3 Power supply: voltage in -
4 Power supply: voltage in +
5 Signal cable B
6 Signal cable A
7 Shielding wire (attached to Faston connectors in the housings of the remote converter and the probe electronics hous-
ing)
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
on page 57
www.krohne.com
ELECTRICAL CONNECTIONS