KROHNE OPTIFLEX 8200 C Handbook page 112

Guided radar (tdr) level transmitter for liquids at high temperature and pressure
Hide thumbs Also See for OPTIFLEX 8200 C:
Table of Contents

Advertisement

OPERATION
6
• After you enter 1.0.0 Advanced Setup
Setup.
Setup
Setup
Setup
• Push [> > > > ] to start the procedure.
• Push [ ] or [ ] to change the Application Type
Compensation option, then set this menu item to "LEVEL WITH GAS PHASE COMPENSATION".
If you have the Interface Capability option, then set this menu item to "LEVEL + INTERFACE
MIXED", "LEVEL + INTERFACE UNMIXED" or "INTERFACE (FULLY SUBMERGED PROBE)".
Push [^ ^ ^ ^ ] to go to the next step.
• ALTERNATIVE STEP A:
ALTERNATIVE STEP A:
ALTERNATIVE STEP A: If you know the dielectric constant value of the tank contents, then
ALTERNATIVE STEP A:
push [> > > > ] (Known) to enter the value. Push [> > > > ] to move the cursor to the next digit on the right. If
the cursor is on the last digit, push [> > > > ] again to go back to the first digit. Push [ ] to decrease
the digit value and [ ] to increase the digit value. Push [^ ^ ^ ^ ] to go to the next step.
• ALTERNATIVE STEP B:
ALTERNATIVE STEP B:
ALTERNATIVE STEP B: If you do not know the dielectric constant value of the tank contents,
ALTERNATIVE STEP B:
then push [ ] (Unknown) to give the product family. Push [ ] or [ ] to change the Product
Family
Family parameter. Push [^ ^ ^ ^ ] to go to the next step.
Family
Family
• Push [^ ^ ^ ^ ] again and again to go back to the Store
• Push [ ] or [ ] to set the screen to "STORE YES" and push [^ ^ ^ ^ ].
i
The device will save the new settings and go back to normal mode.
If the device cannot find the level signal after you do the procedure in menu item 1.4.0
Application Setup, then you can also manually change the threshold to find the signal. Do this
Application Setup
Application Setup
Application Setup
procedure:
• Look at the level pulse amplitude value on left side of the first screen in menu item 2.5.4 Level
Threshold.
Threshold
Threshold
Threshold
i
Make a note of the amplitude of the correct level signal. Use this value to calculate the new
value for the level threshold. The level threshold value used at this time is shown on right
side of the first screen.
• Push [ ] to change the level threshold value.
• Increase the amplitude of the level threshold value. Push [> > > > ] to move the cursor to the next
digit on the right. If the cursor is on the last digit, push [> > > > ] again to go back to the first digit.
Push [ ] to decrease the digit value and [ ] to increase the digit value.
i
This value must be more than the incorrect signal. We recommend that you set the level
threshold at half the amplitude of the correct signal.
• Push [^ ^ ^ ^ ] again and again to go back to the Store
The threshold increases. The device ignores the interference signal and uses the first
i
signal that it finds.
Interface threshold
The device uses Direct mode to measure the level and interface level of products. If there are
objects in the tank that can cause signal interference, change the interface threshold to ignore
them. Use the same procedure in How to use thresholds
go to menu item 2.5.5 Interface Threshold
For more data about the interface threshold, refer to
item 2.5.5).
112
1.0.0 Advanced Setup menu, 3 × [ ] to go to the menu item 1.4.0 Application
1.0.0 Advanced Setup
1.0.0 Advanced Setup
Application Type parameter. If you have the Dynamic Gas-phase
Application Type
Application Type
How to use thresholds to change the interface threshold, but
How to use thresholds
How to use thresholds
2.5.5 Interface Threshold.
2.5.5 Interface Threshold
2.5.5 Interface Threshold
www.krohne.com
Store screen.
Store
Store
Store screen. Save the settings.
Store
Store
Function description
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
OPTIFLEX 8200 C/F/S
1.4.0 Application
1.4.0 Application
1.4.0 Application
Product
Product
Product
1.4.0
1.4.0
1.4.0
2.5.4 Level
2.5.4 Level
2.5.4 Level
on page 79 (menu

Advertisement