Sony BVP-900 Series System Manual page 97

Video camera system
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

3-1 Internal Boards
DM-116 board
3
2
4
1 S4 switch
Selects the direction of the prompter signal flow
between the CCU and camera when the BVP-950/
950P with the CA-570/570P attaches is connected to
the CCU-700A/700AP.
CCU → CAM: The prompter signal from the CCU is
output from the PROMPTER/GENLOCK
connector on the CA-570/570P.
CAM → CCU: The signal input to the PROMPTER/
GENLOCK connector on the CA-570/570P is sent
to the CCU.
Factory setting: CCU → CAM
3-16
Chapter 3 Initial Settings
A
B
C
S4
1 S4 switch
2 S1 switch
D
S1
E
F
G
1
Note
When you set the S4 switch to CAM→CCU, change
the connection of the RF cable (green) on the DM-116
board. Then the setting of the S5 and S6 switches on
the DM board of the CCU-700A/700AP should be
changed from TX to RX.
2S1 switch
For factory use only.
Factory setting: PROMPT
Note
Do not change the factory setting.
C C U
C A M
C A M
C C U
C C U
C A M
C A M
C C U

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-900pBvp-950Bvp-950p

Table of Contents