4-2 Preparations for Adjustments

4-2-3 RCP Assignment

The RCP assignment function permits you to change
the camera control units (CCU) to be controlled with
the remote control units (RCP) connected to the CNU-
700 without changing the cable connections.
The initial setting assigns the RCP connected to the
RCP1 connector to control the CCU (or camera)
connected to the CCU1 connector, the RCP connected
to the RCP2 connector to control the CCU (or camera)
connected to the CCU2 connector, and so on.
Using the RCP assignment function, you can change
this initial assignment as desired. You can also assign
a maximum of three RCP units to control the same
single CCU (or camera).
The RCP assignment is executed using the menu
operation block of the MSU-700A/750 menu or the
internal switches of the CNU-700 while observing the
character display of the CNU-700.
For the character display of the CNU-700, see "6-4
Character Display of the CNU-700."
4-22
Chapter 4 Adjustments
In a system in which a CNU-700 unit is
connected to another CNU-700 unit
The RCP assignment can be performed from the MSU-
700A/750 connected to each CNU-700.
Example:
CNU(1)
MSU
The MSU-700A/750 connected as shown in the above
figure can execute the assignment of the RCP units
connected to CNU(1). To assign the RCP units
connected to CNU(2), first change the connection of
the MSU-700A/750 to CNU(2) and then execute
assignment.
Note that the camera connected to CNU (1) cannot be
controlled from the RCP unit connected to CNU (2).
The control range of the RCP unit is limited to the
single CNU.
Notes
• It is recommended to assign three RCP units at
maximum to a single camera.
If you connect four or more RCP units to a single
camera, some of the RCP units may be disabled.
• A single RCP cannot control multiple cameras.
• When the RCP assignment operation is completed,
the PANEL ACTIVE, IRIS/MB ACTIVE and PARA
buttons on all the RCP units go dark. To use the
RCP units, press and light the buttons as required.
• When using the CNU-500, the RCP assignment
cannot be changed.