3-1 Internal Boards
4 CCU PAINT switch
Set to CLEAR for making adjustment using the
switches and controls on the internal boards of the
CCU-550A/550AP. The center value of the adjustable
range is retrieved.
Factory setting: left
5 BUZZER switch
Set to ON to use the buzzer.
Factory setting: OFF
6 BUZZER LEVEL control
Adjusts the sound level of the buzzer.
Factory setting: MAX
7 CAM POWER (camera power) switch
Turns ON or OFF the BVP-950/950P camera head.
When the power of the camera head is ON, this switch
turns the power OFF; when the power of the camera
head is OFF, this switch turns the power ON.
8 S108 switch
Not used.
Factory setting: OFF
9 S104 switch
S104-1: Not used
Factory setting: OFF
S104-2: Selects whether the warning display appears
on the MSU-700A/750, RCP-700-series units, and
CNU-700/500 when no external sync signal is
supplied to the CCU.
ON: No warning display appears.
OFF: Warning display appears.
Factory setting: OFF
S104-3: Selects the signal output from the CCU when
the power of the camera is OFF.
ON: A color bar signal is output.
OFF: An output signal is muted.
Factory setting: OFF
S104-4: Selects a method to control the signal output
from the PIX and WF connectors.
ON: Control from the MSU-700A/750 only.
OFF: Control from the MSU-700A/750 and RCP-
700-series unit.
Factory setting: OFF
S104-5 to S104-7: Not used
Factory setting: OFF
3-28
Chapter 3 Initial Settings
S104-8: When set to ON, all analog control data are
reset to the center value and all switch settings are
reset to the factory settings when the power is
turned ON.
Factory setting: OFF
Notes
• Setting of this switch is effective only on the camera
whose camera number set with the S103 switch is 96
or lower.
• If all switches 1 to 8 of the S103 switch is set to ON
with the S104-8 switch set to ON, the hours meter on
the AT board is reset.
0S103 (CCU No.) switch
Sets the camera number of the system in which the
CNU-700/500 is not used.
Factory setting: All OFF
For details, see "3-2-5 Setting the Camera Number and
Group Number."
!¡S401 (R TALLY POWER/CONTACT) switch
!™S404 (R TALLY POWER/TTL) switch
Set properly according to the standards of the red tally
signal input to the INCOM/TALLY/PGM connector
on the rear panel.
Switch settings and input signals are shown in the table
below.
Factory setting: POWER
!£S402 (G TALLY POWER/CONTACT) switch
!¢S403 (G TALLY POWER/TTL) switch
Set properly according to the standards of the green
tally signal input to the INCOM/TALLY/PGM
connector on the rear panel.
Switch settings and input signals are shown in the table
below.
Factory setting: POWER
Switch
Contact
S401, S402
Contact
S404, S403
Any position Power
Signal
Power (+24 V)
TTL
Power
Power
TTL