3-1 Internal Boards
7 S201 (AUTO/MANU) switch
Sets the cable compensation of a triax cable.
AUTO: For automatic cable compensation detecting
the cable length automatically.
MANU: For manual cable compensation with the
S202 switch.
Factory setting: AUTO
8 S202 (CABLE LENGTH SELECT) switch
Set to the appropriate position according to the length
of a triax cable that connects BVP-950/950P and the
CCU-550A/550AP when the S201 switch is set to
MANU.
Factory setting: 1 (120 m)
Cable length (center value)
Switch
setting FUJIKURAø8.5 FUJIKURAø14.5 Belden 9238
1
120 m
240 m
(394 feet)
(787 feet)
2
360 m
720 m
(1,181 feet)
(2,362 feet)
3
600 m
1,200 m
(1,969 feet)
(3,937 feet)
3-34
Chapter 3 Initial Settings
AU-236 board
RV100
1
S2
S3
2
1S5 (OPEN/GND) switch
When a dynamic microphone is connected to the
INCOM connector on the front panel, set to the
180 m
appropriate position according to the microphone type.
(591 feet)
OPEN: For balanced type
540 m
(1,772 feet)
GND: For unbalanced type
900 m
Factory setting: OPEN
(2,953 feet)
2S4 (DYN/CM) switch
Set to the appropriate position according to the
microphone connected to the INCOM connector on the
front panel.
DYN: For a dynamic microphone
CM: For a carbon microphone
Factory setting: CM
S5
S1
D
A
B
C
1 S5 switch
S4
2 S4 switch