YC board (only on the CCU-700A)
8 S821 switch
9 S201 switch
!º S3971 switch
1 Power indicators
2 Y3 switch
3 Y3 control
1 Power indicators
Light when the specified power is supplied to the YC
board.
2 Y3 switch
Turns the Y3 signal ON or OFF.
3 Y3 control
Adjusts the Y3 signal level.
4 SI switch
Turns the SI signal ON or OFF.
5 SI control
Adjusts the SI signal level.
S821
S201
S3971
YC
BLACK
Y3
S1
Y COMB
BALANCE
–12 –5 +5 +12
LEVEL
LEVEL
LEVEL
Y
R-Y
OFF ON
OFF ON
6 Y COMB control
Adjusts the cross color of the VBS signal.
7BLACK LEVEL control
Adjusts the black level of the Y, R–Y, B–Y signals.
8S821 (TEST) switch
Uses to adjust the board.
9S201 (Y COM ON/OFF) switch
0S3971 (R–Y COMB ON/OFF) switch
!¡ S1391 (B–Y COMB ON/OFF) switch
Turns the COMB filter ON or OFF.
!¡ S1391 switch
S1391
B-Y
7 BLACK LEVEL control
6 Y COMB control
5 SI control
4 SI switch
Chapter 3 Initial Settings