To operate on the CNU-700
For a CCU (or camera) to which no MSU-700A/750 is
connected, the RCP assignment can be performed
using the internal switches of the CNU-700.
Operating procedure
AT
MODE
+5
UP
1
Set the MODE switch to 2.
The message "RCP Assignment" appears on the
monitor screen.
2
Press the SET/CANCEL switch (S6) towards SET.
The setting status of the control system is
displayed on the monitor screen.
3
Move the cursor on the screen to the desired
position using the UP/DOWN switch (S5).
Each time you press the switch towards DOWN,
the cursor moves to the right or goes down when it
reaches the right edge of the frame.
Each time you press the switch towards UP, the
cursor moves to the left or goes up when it reaches
the left edge of the frame.
4
Press the SET/CANCEL switch (S6) towards SET.
Repeat steps 3 and 4 for other connections to be
changed.
To disconnect an RCP
Press the SET/CANCEL switch (S6) towards
CANCEL in step 4.
CHARACTER
PHASE
DOWN SET CANCEL
SET/CANCEL switch
UP/DOWN switch
MODE switch
When the assignment is completed
5
Repeatedly press the UP/DOWN switch (S5)
towards UP until the cursor reaches the SAVE
position outside the frame.
6
Press the SET/CANCEL switch (S6) towards SET.
The assignment set in steps 3 and 4 is written to
nonvolatile memory.
7
Return the MODE switch to 0.
To resume the initial assignment
In the initial assignment, the CCU numbers match the
RCP numbers.
1
Set the MODE switch to 4.
The message "Default Panel Assignment" appears.
2
Press the SET/CANCEL switch towards SET.
3
Press the SET/CANCEL switch towards SET
again.
The "ON" indication in inverse video returns to its
original status.
4
Set the MODE switch to 2.
The message "RCP Assignment" appears.
5
Press the SET/CANCEL switch (S6) toward SET.
The setting status of the control system is
displayed.
6
Repeatedly press the UP/DOWN switch (S5)
towards UP until the cursor reaches the SAVE
position outside the frame.
7
Press the SET/CANCEL switch (S6) towards SET.
The RCP assignment returns to its initial setting.
8
Return the MODE switch to 0.