2 S351 switch
Selects whether to monitor the microphone input
signal using a headset connected to the INCOM
connector.
ON: To monitor the signal
OFF: To not monitor the signal
Factory setting: OFF
3 S800 switch
Selects whether to supply +12 V power to the
microphone connected to the CA-570/570P.
ON: Supplies +12 V A/B power.
OFF: Supplies no power.
Factory setting: OFF
Note
If the MIC POWER switch on the rear panel is set to
OFF or +48 V, no A/B power is supplied even if the
S800 switch is set to ON.
4 S700 switch
Selects whether to supply +48 V power to the
microphone connected to the CA-570/570P.
ON: Supplies +48 V phantom power.
OFF: Supplies no power.
Factory setting: OFF
5 S200 switch
S200-1: Selects whether to activate the function to turn
the battery alarm indicator ON/OFF when a battery
alarm signal is detected.
ON: The battery alarm indicator lights.
OFF: The battery alarm indicator does not light.
Factory setting: OFF
S200-2: When a CCU is connected to the CA-570/
570P, this switch specifies whether power is
supplied from the REMOTE connector or not.
ON: When a CCU is connected, the power is
automatically turned off. When the camera is used
as stand-alone, the power is turned on.
OFF: The power is always supplied from the
REMOTE connector.
Factory setting: ON
6 S100 switch
Selects the signal output from the TEST OUT
connector.
S100-1: Disables automatic switching between the
playback video signal and the return video signal.
ON: Outputs the playback video signal.
OFF: Outputs the return video signal when a CCU
is attached; outputs the playback video signal when
a VTR is attached.
Factory setting: OFF
S100-2: Specifies output of the VBS signal from the
camera or the return/playback video signal.
ON: Outputs the VBS signal from the camera.
OFF: Outputs the return or playback video signal.
Factory setting: OFF
S100-3: Selects whether the control signal from the
RET CONT connector is received or not.
ON: Outputs the return video signal only when a
return control signal is L.
OFF: Outputs the return video signal only when a
CCU is connected.
S100-4: Selects either a VBS video signal output or
monitor signal output.
ON: Outputs the monitor signal.
OFF: Outputs the VBS signal.
The various combinations of switch S100 settings and
their corresponding video output signal are as follows:
S100-1 S100-2 S100-3 S100-4 RET CONT Video output signal
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
Return video
(When a CCU is
connected)
Playback video
(when a VTR is
connected)
Playback video
VBS video
Monitor video
L
Return video
(when a CCU is
connected)
L
Playback video
(when a VTR is
connected)
H
VBS video
L
Return video
(when a CCU is
connected)
L
Playback video
(when a VTR is
connected)
H
Monitor video