Note
Before creating the OHB file, perform Auto Level
Setup with the reference file or press the STANDARD
button on the MSU-700A/750 or the RCP-series panels
to set the camera to the standard settings.
Note that, however, the auto level setup is to be
performed after "All Preset" (see "3-3-1 Resetting the
Control Signals") is executed on the camera's menu.
Operating procedure
1
While holding the ENTER/CANCEL switch
upward to ENTER, set the DISPLAY switch to
MENU.
The Maintenance menu appears in the viewfinder.
Maintenance menu
* Maintenance Menu *
System Setup
Reference Store
Lens File Store
OHB File Store
Auto Iris Setup
RPN Correct
29F040-BVP-900 X.XX X
menu sel --> enter
2
Move the cursor to "OHB File Store" by turning
the MIC1 LEVEL control, then press the control.
The OHB File Setup menu now appears.
OHB File Setup menu
* OHB File Setup *
Reset OHB File
Auto Black Shading
Auto White Shading
Auto Black Balance
3D Shading : ON
Store
3
Adjust the items to be stored in the OHB file.
1) Move the cursor to one of the items (Auto Black
Shading, Auto White Shading or Auto Black
Balance) using the MIC1 LEVEL control.
2) Press the control.
Auto Setup for that item begins.
To activate the 3D shading compensation for Auto
White Shading, set the cursor to "3D Shading" and
press the MIC1 LEVEL control to set it to "ON."
When Auto setup is completed, the message
"Completed" appears.
To cancel the auto setup
Press the MIC1 LEVEL control again. The
message "Break" appears, then the status before
starting Auto setup is resumed.
4
Move the cursor to the "Store" line by turning the
MIC1 LEVEL control, then press the control.
Reading of the current settings begins.
When reading is completed
The read data are stored in the OHB unit as the
OHB file.
When file storage is completed, the message
"Completed" appears.
5
Press the ENTER/CANCEL switch downward to
CANCEL to return to the Maintenance menu.
To clear the OHB file data
Move the cursor to "Reset OHB File" on the OHB File
Setup menu, then press the MIC1 LEVEL control.
To release the Maintenance menu
Return the DISPLAY switch to OFF.