CONNECT BERT screen

6 - 10

To stop the loop test

Highlight STOP TEST and press SELECT.
The loop is removed from the line and the status line
displays ON HOOK.
This screen is displayed when you choose to run BERT
on the B or D channel. It is the same as the screen
displayed during B channel BERT—see BERT
CONNECTED Screen in Chapter 10.
To display the CONNECT BERT screen:
In the LINE BERT menu, select CONNECT BERT.
Running the BER test
When you select the CONNECT BERT option, the test
begins automatically.
To stop the BER test
Move the cursor to the STOP TEST option and press
SELECT.
The results of the test are now displayed on the screen.
To store the test results
While the test is in progress, press F6—EXIT.
aurora
stops the test and stores the results. Up to
Duet
30 BERT results can be stored at any one time.
To view the stored results, choose RESULTS from
the MAIN menu. You can view results even after
aurora
has been switched off and on again.
Duet
To restart the BER test
Return to the D CHANNEL BERT menu and select
CONNECT BERT.
428856