Agilent Technologies aurora Duet User Manual page 190

Basic & primary rate isdn tester
Table of Contents

Advertisement

Duet
aurora
Basic & Primary Rate ISDN Tester - User Guide
F6
F3
Information displayed
If there is an incoming CLEAR CALL request, aurora
stops the BER test and stores the results.
10 - 14
Displays further function keys available
MORE
to you, as follows:
Displays information about the ISDN
INF
call. For details, see The main function
keys in Chapter 4.
Lines 4 to 9 display the BER test results, updated
approximately each second. Results with very large
or very small values are displayed in exponential
format as described for the BERT RESULTS screen.
ELAPSED TIME
(HH:MM:SS)
RX KBITS
kilobits
BIT ERRS
BER
ES
US
S-LOSS
SES
DM
If the BER test is a timed test, the results are stored
and a PASS/FAIL indication is displayed on line 10.
Times and pass / fail thresholds are defined using
the BERT SETUP screens.
Line 15 displays the following STATUS messages:
CONNECTED (an end to end link is established),
BERT CONNECTED (an end to end link is
established and a test is in progress) and CLEARED
(the link has been cleared down).
Elapsed time of BER test
Number of received
Bit error count
Bit Error Rate
Errored Second
Unavailable Seconds
SYNC loss
Severely Errored Seconds
Degraded Minutes