T1 TEST INFORMATION screens
Issue 2 - 05/00
Function keys
F6
Cancels any test and/or test pattern that
EXIT
is in progress and returns to the MAIN
menu.
These screens display the error counters and performance
settings associated with the current test. They also allow
you to inject errors into the test stream.
There are three information screens, displaying
information on the Bit Error Status, Error Counts and T1
Error Ratios.
To display the T1 TEST INFORMATION screens
The first screen (BIT ERROR STATUS) is displayed
automatically when you start the test. To display each of
the other screens in turn, press F2—NXT.
BIT ERROR STATUS screen
This is the first screen displayed when you begin the test.
The BIT ERROR STATUS screen displays the elapsed time
and counters for the Physical Layer errors listed below.
To clear all error counters, press F3—CLR.