Calls and Testing for the Protocols
When a SPEECH service test is selected, the call is
disconnected as soon as an ALERTING message is
received.
When the test is complete, a box is displayed for each
channel containing one of the following symbols:
Passed
Failed
A shaded box indicates that the call has failed. The call
clearing cause code is displayed below the channel box.
If a channel cannot be tested because a call is already
active for that channel, then the result is BUSY. This is
indicated by a blank box with a cause code displayed
underneath.
When all channels have been tested, the results are
displayed. The results can also be accessed from the
OUTGOING RESULTS option as described below.
Note:
The results of each BER test are automatically printed to
the comms port when the TRACER SETUP option is set to
RESULTS TO COMMS and the AUTO BERT option is
ON. The results are stored even while aurora
is
Duet
switched off.

Function keys

The function keys for the OUTGOING CHANNEL TEST
screen are the same as for the SERVICE TEST described
earlier in this chapter.