Clearing A Call; Unattended Mode - Agilent Technologies aurora Duet User Manual

Basic & primary rate isdn tester
Table of Contents

Advertisement

Duet
aurora
Basic & Primary Rate ISDN Tester - User Guide

Clearing a call

UNATTENDED mode

6 - 6
To clear a voice call, choose the CLEAR CALL option.
To clear a BER test, press F6—EXIT in the BER test
RESULTS screen.
The CLEARED screen displays a cause code to indicate
why the call cleared. See the Call Clearing Cause Codes
appendix for explanations of the codes. You can also
display an explanation of the code on screen by pressing
F4—CSE.
When aurora
Duet
is in Unattended mode, it will answer
and loop data or speech calls automatically on one or all
B channels while unattended. This allows you to perform
a BER test from a device (e.g. another aurora
Speech and Data modes, to a remote unattended
Duet
aurora
.
When a voice call has been successfully connected, you
will hear 3 beeps and the loopback is connected.
Note:
It is not possible to switch between the B-channels in this
mode.
To display the UNATTENDED screen:
In the MAIN menu, select UNATTENDED.
Duet
), in both
428856

Hide quick links: