IDK MSD-6203 Command Reference Manual page 46

4k 30 supported digital multi switcher, msd-62 series
Hide thumbs Also See for MSD-6203:
Table of Contents

Advertisement

MSD-62 series Command Guide
@GHT / @SHT
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the total number of horizontal dots.
Setting
Command
example
Response
Description Setting the total number of IN8 horizontal dots to "1344".
Setting
Command
example
Response
Description If analog RGB signal or analog YPbPr signal is not input, an error is returned.
Remarks
46
The total number of horizontal dots
@GHT
@GHT, h_total_1, h_total_2, h_total_3, h_total_4, ・・・, h_total_8
@SHT, ch, h_total
@SHT, ch, h_total
h_total_1-8 / h_total: The total number of horizontal dots
400 to 4125 (sampling block should be 13 MHz to 162 MHz)
[Default] depends on input signal
ch: Input channel
0 =All analog inputs, 7 = IN7, 8 = IN8
@GHT
@GHT,2200,2200,0,2640,1344,1792,0,0
"0" is returned to channels without input signal.
@SHT,8,1344
@SHT,8,1344
@SHT,8,1344
@ERR,3
Getting command acquires all channels' statuses.
Setting commands are valid only if analog RGB/analog YPbPr signal is input.