IDK MSD-6203 Command Reference Manual page 60

4k 30 supported digital multi switcher, msd-62 series
Hide thumbs Also See for MSD-6203:
Table of Contents

Advertisement

MSD-62 series Command Guide
@GOF / @SOF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
@GMT / @SMT
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
60
Priority of input channel automatic switching (ON to OFF)
@GOF, out
@GOF, out, in1_priority, in2_priority, in3_priority, in4_priority, ・・・, in8_priority
@SOF, out_1, in1_priority, in2_priority・・・, in8_priority (, out_2, in1_priority・・・)
@SOF, out_1, in1_priority, in2_priority・・・, in8_priority (, out_2, in1_priority・・・)
out, out_1-8: Output channel
0 = All outputs, 1 = OUT1 to 8 = OUT8
in1_priority-in8_priority: Priority
0 = OFF, 1 = priority (high) to 8 = priority (low)
@GOF,1
@GOF,1,1,2,3,4,5,6,7,8
Getting the set priority of OUT1's automatic switching.
IN1>IN2>・・・>IN8
@SOF,1,8,7,6,5,4,3,2,1
@SOF,1,8,7,6,5,4,3,2,1
Setting the priority of OUT1's automatic switching to IN8>IN7>・・・>IN1.
Masking time after automatic switching of input channel
@GMT
@GMT, time_1, time_2, time_3, ・・・, time_8
@SMT, ch_1, time_1 (, ch_2, time_2・・・)
@SMT, ch_1, time_1 (, ch_2, time_2・・・)
time_1-8 : Masking time
0 = 0 sec. to 999999 = 999.999 sec. [Default] 0 sec.
ch_1-8: Output channel
0 = All outputs, 1 = OUT1 to 8 = OUT8
@GMT
@GMT,2000,2000,2000,2000,10000,10000,10000,10000
Getting the set masking time after automatic switching of input channel.
OUT1 to OUT4: 2000 ms (2 sec.), OUT5 to OUT8: 10000 ms (10 sec.)
@SMT,1,2000,2,2000,3,10000,4,10000
@SMT,1,2000,2,2000,3,10000,4,10000
Setting the masking time to 2000 ms. (2 sec.) for OUT1 and OUT2, 10000 ms.
(10 sec.) for OUT3 and OUT4.