MSD-62 series Command Guide
@GFF / @SFF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting input channel switching effect.
Setting
Command
example
Response
Description Setting OUT1 switching effect to FADE OUT/IN.
Remarks
@GFT / @SFT
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set switching speed of video input channel.
Setting
Command
example
Response
Description Setting OUT1 switching time to 400 ms.
Remarks
54
Video switching effect
@GFF
@GFF, switching_1, switching_2, switching_3, ・・・, switching_8
@SFF, ch_1, switching_1 (, ch_2, switching_2・・・)
@SFF, ch_1, switching_1 (, ch_2, switching_2・・・)
switching_1-8: Video switching effect
0 = CUT,
1 = FADE OUT/IN,
2 = FREEZE + FADE OUT/IN [Default],
3 = LEFT→RIGHT WIPE,
4 = RIGHT→LEFT WIPE,
5 = TOP→BOTTOM WIPE,
6 = BOTTOM→TOP WIPE
ch_1-8: Output channel
0 = All outputs, 1 = OUT1 to 8 = OUT8
@GFF
@GFF,0,0,0,0,1,1,1,1
OUT1 to OUT4: CUT, OUT5 to OUT8: FADE OUT/IN
@SFF,1,1
@SFF,1,1
An error occurs if this menu is set to one of "3" to "6" (WIPE) while video
combination mode is enabled.
Video switching speed
@GFT
@GFT, time_1, time_2, time_3, ・・・, time_8
@SFT, ch_1, time_1 (, ch_2, time_2・・・)
@SFT, ch_1, time_1 (, ch_2, time_2・・・)
time_1-8: Switching speed
100 = 0.1 sec. to 2000 = 2 sec.
[Default] 350 = 0.35 sec.
Set the value by 10 ms. If you set a value other than 0 for the lower 1 digits, these
values will be rounded down. (For example, if you set it to 395, the speed is set to
390 ms.)
ch_1-8: Output channel
0 = All outputs, 1 = OUT1 to 8 = OUT8
@GFT
@GFT,400,400,400,400,350,350,350,350
OUT1 to OUT4: 400 ms, OUT5 to OUT8: 350 ms
@SFT,1,400
@SFT,1,400