@GTF / @STF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
Blinking time of sink device power switch
@GTF, switch_1 (, switch_2・・・)
@GTF, switch_1, flash_1 (, switch_2, flash_2・・・)
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
switch_1-13: Key group
0 = All keys, 1 = COMMAND A to 5 = COMMAND E
10 = DISPLAY1 POWER to 17 = DISPLAY8 POWER
flash_1-13: Blinking time
-1 = Links during control command execution,
0 = Not blink,
1 to 1000 = Blinks for 1 sec. to 1000 sec.
[Default] COMMAND A to COMMAND E = 0,
DISPLAY1 POWER to DISPLAY8 POWER = -1
@GTF,1
@GTF,1,-1
Getting blinking time of COMMAND A.
The switch will be blinked while control command is being executed.
@STF,1,5
@STF,1,5
Setting COMMAND A to blink 5 seconds after control command execution starts.