@GNP / @SNP
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set input position.
Setting
Command
example
Response
Description Setting IN1 horizontal and vertical input positions are to -50 and +20, respectively.
Remarks
Input position
@GNP
@GNP, h_position_1, v_position_1, h_position_2, v_position_2・・・, h_position_8,
v_position_8
@SNP, ch_1, h_position_1, v_position_1 (, ch_2, h_position_2, v_position_2・・・)
@SNP, ch_1, h_position_1, v_position_1 (, ch_2, h_position_2, v_position_2・・・)
h_position_1-8: Horizontal input position
-Horizontal input size to +Horizontal output resolution [Default] 0
v_position_1-8: Vertical input position
-Vertical input size to +Vertical output resolution [Default] 0
ch_1-8: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
@GNP
@GNP,-50,20,0,0,0,0,0,0,0,0,0,0,0,0,0,0
N1: horizontal input display is -50, vertical input display is +20.
Other inputs: horizontal and vertical input positions are 0.
@SNP,1,-50,20
@SNP,1,-50,20
If resolutions differ depending on output, the OUT1 output resolution will be the
standard.