IDK MSD-6203 Command Reference Manual page 37

4k 30 supported digital multi switcher, msd-62 series
Hide thumbs Also See for MSD-6203:
Table of Contents

Advertisement

@GST / @SST
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set saturations.
Setting
Command
example
Response
Description Setting IN5 saturation to 105%.
Remarks
@GSU / @SSU
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the input black level.
Setting
Command
example
Response
Description Setting the IN5 black level to +7.5%.
Remarks
Saturation
@GST
@GST, saturation_1, saturation_2, saturation_3, saturation_4, ・・・, saturation_8
@SST, ch_1, saturation_1 (, ch_2, saturation_2・・・)
@SST, ch_1, saturation_1 (, ch_2, saturation_2・・・)
saturation_1-8: Input saturation
0 to 200
[Default] 100
ch_1-8: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
@GST
@GST,100,100,100,100,105,100,100,100
IN5: 105 %, other inputs: 100 %
@SST,5,105
@SST,5,105
Hue can be set up to 200%. However, if the dot clock of the input signal exceeds
170 MHz, 100% is applied regardless of this setting.
Black level
@GSU
@GSU, setup_1, setup_2, setup_3, setup_4, ・・・, setup_8
@SSU, ch_1, setup_1 (, ch_2, setup_2・・・)
@SSU, ch_1, setup_1 (, ch_2, setup_2・・・)
setup_1-8: Input black level
-20 = -20 × 0.5 (-10.0 %) to +20 = +20 × 0.5 (+10.0 %)
[Default] ±0 = ±0.0 %
ch_1-8: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
@GSU
@GSU,0,0,0,0,15,0,0,0
IN5: +7.5%, other inputs: 0%.
@SSU,5,15
@SSU,5,15
MSD-62 series Command Guide
37