Figure 7-39 Bottom View of the RLS showing the Sensor Slave PCBA Bracket Screws
7.17.3 Sensor Slave Assembly Replacement
This procedure assumes that the Sensor Slave Assembly was removed in Section
7.17.2.
1.
Position the bracket inside of the library's chassis, aligning the three threaded
holes with the screw holes in the bottom of the RLS.
2.
Using a No. 1 Phillips screwdriver, replace the three 6-32 x 1/4 flat-head screws
on the bottom of the RLS that hold the Sensor Master PCBA bracket in place.
See Figure 7-39.
3.
Reconnect the ribbon cable to the SENSOR connector on the right side of the
PCBA as seen from the front of the RLS. See Figure 7-38.
7.17.4 Sensor Master Assembly Replacement
This procedure assumes the Sensor Master Assembly was removed in Section 7.17.1.
1.
Carefully position the bracket in between the left and right sides of the chassis,
aligning the threaded holes with the screw holes on the sides of the RLS. See
Figure 7-37.
2.
Using a 5/64-inch Allen (hex) wrench, replace the two Allen-head screws that
were removed earlier from the left side of the RLS that hold the Sensor Master
PCBA bracket in place. See Figure 7-37.
3.
Using a No. 2 Phillips screwdriver, replace the two flat-head screws that were
removed earlier from the right side of the RLS that hold the Sensor Master
PCBA bracket in place. See Figure 7-37.
7-60
Front of RLS
Remove these 3 screws
Field–Replaceable Units (FRUs)
501510 Rev. S