Door Lock Pcba; Door Lock Pcba Removal - Qualstar RLS-4470 Technical & Service Manual

Tape library; rls-4000 series; rls-5000 series; rls-6000 series; rls-8000 series;
Table of Contents

Advertisement

8.
If the RLS is rack-mounted, retract it back into the rack by following Section
7.5.2.
9.
Proceed to Section 7.24 to calibrate the RLS

7.15 Door Lock PCBA

P/N 501587-01-8
The Front Panel/Door Assembly must be removed from the RLS before the Door Lock
PCBA can be replaced. The RLS does not need to be calibrated after replacing the
Door Lock PCBA FRU.
Tools Required:
No. 1 Phillips Screwdriver
No. 2 Phillips Screwdriver
Chassis Screws (4)
Figure 7-33 Door Lock PCBA and Chassis Screws

7.15.1 Door Lock PCBA Removal

1.
Remove the Carriage Assembly as described in Section 7.7.1
2.
Remove the Front Panel/Door Assembly from the RLS as described in Section
7.10.1.
3.
Disconnect the ribbon cable from the SENSOR connector on the rear of the Door
Lock PCBA.
4.
Using a No. 1 Phillips screwdriver, remove the two Door Lock PCBA mounting
screws. See Figure 7-33.
7-54
Field–Replaceable Units (FRUs)
Door Lock PCBA
Mounting Screws (2)
501510 Rev. S