Filter
This value is the number of minutes since the Air Filter was last changed.
•
Grips
This value is the number of times that the cartridge Gripper mechanism has
been cycled.
•
Minutes
This value is the number of power-on minutes.
•
Moves
This value is the number of cartridge moves.
•
Picks
This value is the number of times that a cartridge has been removed from a
drive or storage location.
•
Places
This value is the number of times that a cartridge has been placed into a drive
or storage location.
•
PowerOn
This value is the number of times that the power has been turned on.
•
Resets
This value is the number of Executive CPU resets, including power-on resets
and SCSI bus resets.
•
S Cmnds
This value is the number of SCSI commands received by the RLS.
4.5 The Maintenance\Display Voltage status screen
The
Display Voltage
The +24V supply is the incoming voltage to the Executive PCBA from the power sup-
ply module(s). The +5V and +3.3V supplies are the output of the switch-mode regula-
tor on the Executive PCBA.
501510 Rev. S
M••••Display Voltage
+3.3V:
dd.dd
+5V:
dd.dd
+24V:
dd.dd
status screen displays the current power supply voltages.
The Maintenance Menu
4-5