3.
Remove the Tape Drive(s) currently installed in the left half of the Drive Bay
(the left drive for all models except the RLS-44xx where the two left drives must
be removed – see Section 7.11.1 for details).
In the next step a small mirror and flashlight may be helpful to see the ribbon cable con-
nection.
4.
In the rear left corner of the Drive Bay, just past the drive platform, is a ribbon
cable running from left to right. Pull that cable to the right to unplug it from the
Storage Array Assembly. See Figure 7-11.
Drive Platform
Figure 7-11 Detailed view of the Ribbon Cable attached to the Storage Array Assembly
5.
On the Interconnect PCBA, unplug the three ribbon cables. Refer to Figure 7-12.
6.
Use diagonal cutters to cut the cable tie nearest the Executive PCBA that se-
cures the round power cable going to the Executive PCBA.
7.
Remove the Sensor Master Assembly by removing the two No. 1 Phillips screws
on the right side and the two 5/64ths hex-head screws on the left side. Refer to
Figure 7-37. Lift the assembly straight up and place in a safe location.
7-20
NOTE
Ribbon Cable Connector
Field–Replaceable Units (FRUs)
Storage Array
Ribbon Cable