5.4 The Private Menu
The Private menu is only visible after the proper access word has been entered as de-
scribed in Section 5.3. Menu items that are shaded are for Qualstar personnel use on-
ly and are not described within this manual. Remember that status screens are for
display purposes only and contain no editable items.
Manu items in the Private menu are locked by a combination of the four RLS security
locks. If a SECURITY message appears, the user must first unlock the security locks before
proceeding. Use the procedure in section 5.2 to enter the Security menu and disable the
Master Security Lock. The user can also disable the Inventory Lock while the Security
menu is displayed.

5.4.1 The Private\CALIBRATE command

The
CALIBRATE
so, because it involves risk. For example, if the
rectly, improper Handler operation may result. Therefore, if the Handler is properly
picking and placing cartridges, and the user does not have a specific reason for using
the
CALIBRATE
Changing a Barcode Reader, Tape Drive Assembly or Power Supply module does not
require the RLS be calibrated. However the RLS must be calibrated whenever the fol-
lowing items are changed: Handler, Storage Array, Carousel, Executive PCBA or Sen-
sor Master PCBA.
5-10
•••••••••••••Private
Access: ??????????
•Adapter
•Cabling
•Calibration
CALIBRATE
CLEAR ACCESS
•Configuration
•Control Panel
•Display A/D
•Display Locations
•Display Positions
•Drivebay
•Executive
•I2c
•Magazine
OPEN VIOP WINDOW
REBOOT
RESET SCSI BUS
•Sensor
NOTE
command should not be executed without a specific reason for doing
command, recalibrating the RLS is not recommended.
The Private Menu
command is used incor-
CALIBRATE
501510 Rev. S