3.
With the Front Panel/Door open, use a No. 2 Phillips screwdriver to reinstall the
two screws that secure the RLS to the front rack posts. See Figure 7-2.
4.
Gently lift and push the Front Panel/Door until it latches shut.
5.
Reconnect any cables that were disconnected in of Section 7.5.1.

7.6 Top Cover

Tools Required: No. 2 Phillips Screwdriver
Right Side of RLS
Figure 7-3 The Top Cover

7.6.1 Opening the Top Cover

1.
Remove power from the RLS by first pressing the power switch off and then re-
moving the power cord (two power cords if dual-redundant power supply mod-
ules are installed).
2.
If the RLS is rack-mounted, extend it from the rack by following Section 7.5.1.
3.
Use a No. 2 Phillips screwdriver to remove the four screws from the right (as
viewed from the front) edge of the Top Cover as shown in Figure 7-3.
4.
Lift the Top Cover until the support arm locks in its open position.

7.6.2 Closing the Top Cover

1.
Lift the Top Cover all the way up, and then pull the support arm outwards to
unlatch it. Gently lower the Top Cover.
501510 Rev. S
Top Cover
in open position.
Field–Replaceable Units (FRUs)
Support Arm
7-11