Sensor Slave Assembly Removal - Qualstar RLS-4470 Technical & Service Manual

Tape library; rls-4000 series; rls-5000 series; rls-6000 series; rls-8000 series;
Table of Contents

Advertisement

7.
Using a 5/64-inch Allen (hex) wrench, remove the two Allen-head screws from
the left side of the RLS that hold the Sensor Master PCBA bracket in place. See
Figure 7-37.
8.
Dip the left side of the bracket down so that it clears the Interconnect PCBA and
then remove it from the chassis.

7.17.2 Sensor Slave Assembly Removal

Sensor Slave PCBA Bracket
Figure 7-38 The Sensor Slave PCBA Bracket and SENSOR Connector
1.
Disconnect the ribbon cable from the SENSOR connector on the right side of the
PCBA as seen from the front of the RLS. See Figure 7-38.
2.
If the RLS is a tabletop model, slide the RLS forward far enough over the edge of
the table so that the Sensor Slave PCBA bracket screws located on the bottom of
the library can be accessed. See Figure 7-39.
3.
There are three bracket screws located on the bottom of the library. Using a No.
1 Phillips screwdriver, remove the screws as shown in See Figure 7-39.
4.
Remove the Sensor Slave PCBA bracket from the chassis.
501510 Rev. S
Field–Replaceable Units (FRUs)
SENSOR Connector
7-59

Advertisement

Table of Contents
loading

Table of Contents