X-Clear Emitter Pcba Replacement - Qualstar RLS-4470 Technical & Service Manual

Tape library; rls-4000 series; rls-5000 series; rls-6000 series; rls-8000 series;
Table of Contents

Advertisement

3.
Disconnect the ribbon cable from the X-Clear Emitter PCBA. See Figure 7-34.
4.
Using a No. 1 Phillips screwdriver, remove the two screws from the right side of
the RLS that hold the PCBA in place. See Figure 7-35.
5.
Remove the X-Clear Emitter PCBA form the RLS.
Ribbon Cable
Connector
Figure 7-34 X-Clear Emitter PCBA shown with Cover Removed
Front of RLS
Figure 7-35 The X-Clear Emitter PCBA Screws on the Right Side of the RLS

7.16.2 X-Clear Emitter PCBA Replacement

This procedure assumes that the X-Clear Emitter PCBA was removed in Section
7.16.1. The RLS must be calibrated after replacing the X-Clear Emitter PCBA FRU.
7-56
X-Clear Emitter PCBA
5 Cover Bracket Screws
Field–Replaceable Units (FRUs)
Right Side of the
RLS Chassis
2 X-Clear Emitter PCBA
Mounting Screws
501510 Rev. S