Period X
Used primarily for diagnostics, this value represents the period of time that it
takes for the Hall-Effect sensors in the X-Axis brushless DC motor to move be-
tween two points. The maximum value of 65,535 will be shown when the motor
is not moving.
•
Z
This value indicates the current position of the Z-Axis motor. The value de-
creases as the picker moves toward the storage slots. When the carriage is all
the way to the backstop, after a successful POST, the position is zero.
•
Period Z
Used primarily for diagnostics, this value represents the period of time that it
takes for the Hall-Effect sensors in the Z-Axis brushless DC motor to move be-
tween two points. The maximum value of 65,535 will be shown when the motor
is not moving.
5.4.13 The Private\DriveBay status screen
The
Private\DriveBay
•
Address
The I
•
Type
The part number of the Drive Bay microprocessor's firmware.
•
Rev
The revision of the Drive Bay microprocessor's firmware. Leading zeroes are
suppressed.
•
Mode
Normal or Boot modes are possible. Boot occurs during firmware uploading.
•
+24V
The +24V supply voltage to the Drive Bay.
5-20
Private•••••DriveBay
Address:
Type:
dddddddddd
Rev: ddd.ddddd-ddd
Mode:
+24V:
Alarm:
+5V:
Alarm:
•Alarm Limits
•C1:
•C2:
•C3:
•C4:
•Power Left
•Power Right
status screen indicates the status of the Drive Bay board:
2
C address of the Drive Bay microprocessor.
The Private Menu
xx
NORMAL
dd.dd
OFF
dd.dd
OFF
NONE
NONE
NONE
NONE
501510 Rev. S