In the next step a small mirror and flashlight may be helpful to see the ribbon cable con-
nection.
4.
In the rear left corner of the Drive Bay, just past the drive platform, is a ribbon
cable running from left to right. Pull that cable to the right to unplug it from the
Storage Array Assembly. See Figure 7-11.
5.
Using a No. 2 Phillips screwdriver, carefully remove the six screws that secure
the access panel to the rear of the library. See Figure 7-15.
Rear of Library
Figure 7-15 Access Panel on Rear of the Library and Storage Array Removed from Library
6.
If the RLS is not rack-mounted, carefully turn it on its left side (as seen from the
front) so that the Storage Array mounting screws located on the bottom of the li-
brary can be accessed.
7.
There are three or five (model dependent) Storage Array mounting screws locat-
ed on the bottom of the chassis. Using a No. 2 Phillips screwdriver, remove the
screws as shown in Figure 7-14. If the RLS is on its side, hold the Storage Array
Assembly in place with one hand while removing the final screw.
7-26
NOTE
Field–Replaceable Units (FRUs)
Storage Array removed
from the Library.
Access Panel
501510 Rev. S