9. Remove the PCI slot filler, if installed. Keep the filler in a safe place for potential future use.
10. Press the adapter firmly into the expansion slot.
Attention: Incomplete insertion might cause damage to the system board or the adapter.
11. Perform any configuration tasks that are required for the adapter.
If you have other devices to install or remove, do so now. Otherwise, go to "Completing the installation" on
page 85.
Installing an optional ServeRAID adapter memory module
Use this information to install an optional ServeRAID adapter memory module into the server.
To install an optional ServeRAID adapter memory module, complete the following steps:
1. Read the safety information that begins in "Safety" on page v and "Installation guidelines" on page 36.
2. Turn off the server (see "Turning off the server" on page 24) and all attached peripheral devices.
3. Disconnect all external cables and power cords.
4. Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention: Do not allow the server to fall over.
5. Unlock and remove the left-side cover (see "Removing the left-side cover" on page 39).
.
Chapter 2
Installing optional devices
67