Lenovo x3300 M4 7382 Installation And Service Manual page 696

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 217-800-000 : HDD Test Aborted
HDD Test Aborted. The test was canceled.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 217-900-000 : HDD Test Failed
HDD Test Failed. The hard drive self-test detected a failure.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
684
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents