Table 1. Server features and specifications (continued)
• In 2.5" system, two internal SAS
cable connecting SAS RAID
controller to SAS hard drive
backplane. One type of
backplanes will be used to support
eight 2.5" hot-swap HDDs. In
addition, the system will use 2
types of backplanes to support
sixteen 2.5" hot-swap HDDs
• In 3.5" system, two internal SAS
cable is required to support eight
3.5" hot-swap HDDs with the
required backplane
PCI and PCI-X expansion slots:
• Six PCI-e expansion slots on the
system board
– Slot 1: PCI Express 3.0 x8 (x8
wired); full-height, half-length
(requires second processor)
– Slot 2: PCI Express 3.0 x8 (x8
wired) ; full-height, full-length
– Slot 3: PCI Express 3.0 x8 (x4
wired); full-height, half-length
– Slot 4: PCI Express 3.0 x16 (x8
wired); full-height, full-length
– Slot 5: Gen2 PCI Express x4 (x1
wired); full-height, half-length
– Slot 6: Gen2 PCI Express x8 (x4
wired); full-height, half-length,
has PCI-X capability by using a
PCI-e (of Lenovo System x3500
M4 Type 7383) to PCI-X
converter kit
• One PCI-X Slot (optional): 64-bit/
133MHz
Power supply:
• One fixed 460-watt power supply
– None support AEM function
– None support graphic card
– For two microprocessors
installed, the maximum HDD is
up to 4 and the maximum PCIe
cards is up to 3
• Up to two hot-swap power supply
for redundant supply
– 550-watt ac
Notes:
1. None support graphic card
– Maximum altitude: 3050 m
(10,000 ft) & 5°C - 28°C (41°F -
82°F)
– Maximum rate of temperature
change: 5°C/hr (41°F/hr) for
tape drive, 20°C/hr (68°F/hr) for
HDDs
• Power off:
– Temperature: 5°C to 45°C (41°F
- 113°F)
– Relative humidity: 8% - 85%
– Maximum dew point: 27°C
(80.6°F)
• Storage (non-operating)
– Temperature: 1°C to 60°C
(33.8°F - 140°F)
– Altitude: 3050 m (10,000 ft)
– Relative humidity: 5% - 80%
– Maximum dew point: 29°C
(84.2°F)
• Shipment (non-operating)
– Temperature: -40°C to 60°C
(-40°F - 140°F)
– Altitude: 10,700 m (35,105 ft)
– Relative humidity: 5% - 100%
– Maximum dew point: 29°C
(84.2°F)
• Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
"Particulate contamination" on
page 799.
Electrical input:
• Sine-wave input (50 - 60 Hz)
required
• Input voltage automatically
selected
• Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
• Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
• Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.12 kVA
– Maximum: 0.9 kVA
Chapter 1
• Onboard Intel Powerville Gigabit
Ethernet controller with Wake on
LAN support. The controller
provides up to four ports when the
optional Feature on Demand (FoD)
feature is activated.
• Combine "Intel PCH SAS/SATA
RAID controller which supports for
RAID levels 0, 1 and 10 with SW
RAID controller - ServeRAID C105
• Light path diagnostics
• Eight Universal Serial Bus (USB)
2.0 ports:
– Two on the front of the chassis
– Four on the rear of the chassis
– Two internal USB ports: one is
for option USB flash device with
embedded hypervisor, one is
for option USB tape drive
• One serial connector
• One D-Sub VGA connector
Acoustical noise emissions:
• Non-redundant power system,
Idle: 5.5 bels, operating: 5.8 bels
• Redundant power system, Idle: 6.0
bels, operating: 6.3 bels
Chassis
• 4U standing and rack mountable
mechanical
• Physical dimensions: 425 mm
(Height) x 176 mm (Width) x 635
mm (Depth)
• Weight approximately: 29.7 kg
(65.43 lb) when fully configured or
20 kg (42 lb) minimum
.
The Lenovo System x3300 M4 Type 7382 server
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents