Lenovo x3300 M4 7382 Installation And Service Manual page 383

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is one of Pwr Rail A-H Fault, please follow actions in "Power Problems and
Solving Power Problems".
• 80070608-0a01ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080a01ffff or 0x800706080a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:
1. Use the IBM Power Configurator utility to determine current system power consumption. For
more information and to download the utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
Appendix A. Integrated management module II (IMM2) error messages