Lenovo x3300 M4 7382 Installation And Service Manual page 655

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

User Response
Complete the following steps:
1. Reflash backup UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
• I.3818003 [I.3818003] The CRTM flash driver could not lock the secure flash region.
Explanation: CRTM Could not lock secure flash region
Severity
Info
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, (Trained service technician only) Replace the
system board.
• I.3868000 [I.3868000] BOFM: System reset performed to reset adapters.
Explanation: BOFM: System reset performed to reset adapters
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
• I.3868003 [I.3868003] BOFM: Configuration to large for compatibility mode.
Explanation: BOFM: Configuration too large for compatibility mode
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
• I.58015 [I.58015] Memory spare copy initiated.
Explanation: Spare Copy Started
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
• I.580A4 [I.580A4] Memory population change detected.
Explanation: DIMM Population Change Detected
Severity
Info
Appendix B. UEFI/POST diagnostic codes
643

Advertisement

Table of Contents
loading