Lenovo x3300 M4 7382 Installation And Service Manual page 654

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use special
utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ASU Utility.
4. Replace adapter.
• I.3048005 [I.3048005] UEFI has booted from the backup flash bank.
Explanation: Booting Backup UEFI Image
Severity
Info
User Response
Complete the following steps:
1. Refer to service information for this product section on UEFI Recovery to return system to
primary bank.
• I.3808004 [I.3808004] The IMM System Event log (SEL) is full.
Explanation: IPMI System Event Log is Full
Severity
Info
User Response
Complete the following steps:
1. Use IMM Web Interface to clear event log.
2. If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and
Choose Clear IMM System Event Log and Restart Server.
• I.3818001 [I.3818001] The firmware image capsule signature for the currently booted flash bank is
invalid.
Explanation: Current Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
• I.3818002 [I.3818002] The firmware image capsule signature for the non-booted flash bank is
invalid.
Explanation: Opposite Bank CRTM Capsule Update Signature Invalid
Severity
Info
642
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents