Lenovo x3300 M4 7382 Installation And Service Manual page 723

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 201-819-003 : Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 201-820-000 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Lenovo Support website
Latest level of DSA
Appendix C. DSA diagnostic test results
711

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents